Domoticz Plugin

LuxtronikEx

Real-time heat pump monitoring & control for Domoticz

62 Devices & Sensors
5 Languages
Real-time COP Tracking
Zero Dependencies

Features

Smart COP Tracking

Separate efficiency metrics for heating, hot water, and combined — only measured during steady-state operation.

🛡

Intelligent Gating

Blocks sensor updates when the compressor is idle, preventing misleading readings from skewing your data.

🔒

Secure Write Control

All commands validated against an explicit allowlist before touching your heat pump’s EEPROM.

🔄

Multi-Instance Support

Run multiple plugin instances for homes with more than one heat pump, each fully independent.

🌐

5 Languages

Full translations for EN, NL, DE, FR, and PL — including device names, descriptions, and selector options.

🔗

Stable Device IDs

Hardware-based identifiers that persist across IP changes and device renames — no more broken history.

62 Devices at Your Fingertips

Efficiency & Power

COP total 9.81 COP Combined efficiency — higher is better 03/13/2026 9:39 AM
COP heating 11.76 COP Heating-only, gated to steady state 03/13/2026 9:39 AM
COP DHW 4.22 COP Hot water efficiency — lower due to higher temps 03/13/2026 9:39 AM
Working mode Heating Current operating state of the heat pump 03/13/2026 9:39 AM
Power total 1,847 W Electrical input — compressor, pumps, controls 03/13/2026 9:39 AM
Heat out total 5,432 W Thermal output delivered to your home 03/13/2026 9:39 AM
Heating ΔT 6.4° C Δ Supply minus return — heat actually delivered 03/13/2026 9:39 AM
Heating flow 842 L/h Water flow rate through the heating circuit 03/13/2026 9:39 AM

Temperatures

Outside temp 9.2° C Ambient air — drives the heating curve 03/13/2026 9:39 AM
Room temp 21.1° C Reference room for temperature regulation 03/13/2026 9:39 AM
DHW temp 55.6° C Hot water tank temperature 03/13/2026 9:39 AM
Heat supply temp 27.6° C Water leaving the heat pump 03/13/2026 9:39 AM
Heat return temp 21.2° C Water returning from the heating system 03/13/2026 9:39 AM
Source inlet temp 22.7° C Ground source temperature entering the unit 03/13/2026 9:39 AM
Brine ΔT 3.1° C Δ Energy extracted from the ground loop 03/13/2026 9:39 AM
DHW temp target 52.0° C Hot water setpoint — adjustable 30–65°C 03/13/2026 8:57 AM

Controls

Heating mode Automatic Automatic, Party, Holiday, or Off 03/13/2026 8:57 AM
Hot water mode Automatic Independent control from heating mode 03/13/2026 8:57 AM
Cooling On Enable passive or active cooling 03/13/2026 8:57 AM
DHW Power Mode Normal Normal vs Luxury — controls compressor speed 03/13/2026 8:57 AM

Compressor & Statistics

Compressor freq 40 Hz Current compressor speed 03/13/2026 9:39 AM
Compressor capacity 34 % Load relative to maximum capability 03/13/2026 9:39 AM
Superheat 8.2 K Expansion valve health indicator 03/13/2026 9:39 AM
Pressure high 10.74 bar Condenser pressure — system health 03/13/2026 9:39 AM
Last cycle 2.4 hrs Duration of last completed compressor run 03/13/2026 9:12 AM
Compressor runtime 8,412 hrs Lifetime hours — for maintenance planning 03/13/2026 9:39 AM
Compressor starts 3,847 Total starts — indicates cycling behavior 03/13/2026 9:39 AM
Temp adjust +1.0° C Manual heating curve offset ±5°C 03/13/2026 8:57 AM