Migrating from v1

Coming from the original Luxtronik plugin (plugin key luxtronik)? Two SQL scripts copy your history (temperature graphs, energy meters, percentages and switch logs) onto the devices of this plugin, so your graphs continue where they left off.

The two plugins use different keys (luxtronik and luxtronikex), so they can run side by side while you migrate.

Before you start

  • Both plugins installed and running, each with its own hardware entry:
    • the old plugin, typically in plugins/luxtronik-domoticz-plugin/ (key luxtronik)
    • this plugin in plugins/luxtronikex/ (key luxtronikex), see Installation
  • Only one hardware entry of each. The scripts find both plugins by their key and take one entry of each. With more than one heat pump they cannot tell which old entry belongs to which new one, so do not run them on such a setup.
  • sqlite3 on the Domoticz machine (sudo apt install sqlite3 on Debian or Ubuntu).
  • The migration/ folder. It is not in the release zip or on the dist branch. Download discover.sql and migrate.sql from the main branch into a migration/ folder next to domoticz.db. The commands below run from the folder that holds domoticz.db.

Back up first

The migration writes directly into the Domoticz database. There is no undo other than restoring your backup.

Steps

1. Back up the database

sudo systemctl stop domoticz
cp domoticz.db domoticz.db.backup
sudo systemctl start domoticz

2. Let the new plugin create its devices

Add this plugin as hardware (Setup → Hardware) with a temporary name such as HPNEW, and let it run for a few minutes so all devices exist.

3. Preview (optional)

sqlite3 domoticz.db < migration/discover.sql

This only reads. It shows which hardware entries were found, how old and new devices pair up, and how much history each has.

4. Migrate

sudo systemctl stop domoticz
sqlite3 domoticz.db < migration/migrate.sql
sudo systemctl start domoticz

5. Check and clean up

  1. Open the graphs of a few new devices (a temperature, a kWh meter, a COP device) and check that the older history is there.
  2. Disable or delete the old plugin's hardware entry, and remove its plugin folder.
  3. Rename the new hardware entry to the name you want (for example HP).

If something looks wrong, stop Domoticz, put domoticz.db.backup back as domoticz.db, and start Domoticz again.

What gets migrated

  • Temperatures: all sensor history and daily aggregates.
  • Energy meters (kWh): consumption and production history. Cumulative counters are carried over, so Today, Week and Month totals continue seamlessly.
  • Percentages and custom sensors: pump speeds, COP values and similar.
  • Switches and selectors: state change history.
  • Hourly statistics used for usage patterns.

How it works

  • Devices are paired by unit number, not by name, so your language setting does not matter.
  • Only history older than each new device's first value is copied, so nothing is duplicated.
  • Values the new devices logged before the migration are tidied up so graphs join cleanly.

Unit mapping

Old unit New unit Type Device
1 60 Temperature Heat supply temp
2 61 Temperature Heat return temp
3 62 Temperature Return temp target
4 90 Temperature Outside temp
5 91 Temperature Outside temp avg
6 80 Temperature DHW temp
7 15 Setpoint DHW temp target
8 100 Temperature Source inlet temp
9 101 Temperature Source outlet temp
10 120 Temperature Circuit 1 temp
11 121 Temperature Circuit 1 target
12 130 Temperature Circuit 2 temp
13 131 Temperature Circuit 2 target
14 10 Selector Heating mode
15 11 Selector Hot water mode
16 13 Switch Cooling
17 14 Setpoint Temp adjust
18 1 Text Working mode
19 106 Custom Source flow
20 140 Custom Compressor freq
21 92 Temperature Room temp
22 93 Temperature Room temp target
23 30 kWh Power total
24 31 kWh Power heating
25 32 kWh Power DHW
26 40 kWh Heat out total
27 41 kWh Heat out heating
28 42 kWh Heat out DHW
29 50 Custom COP total
30 66 Percentage Heating pump
31 105 Percentage Source pump
32 160 Temperature Hot gas temp
33 161 Temperature Suction temp
34 165 Custom Superheat
35 166 Custom Pressure high
36 167 Custom Pressure low
37 102 Custom Source ΔT
38 63 Custom Heating ΔT
39 12 Selector DHW Power Mode
40 16 Setpoint Room temp setpoint
41 51 Custom COP heating
42 52 Custom COP DHW